PROCESS INSTRUCTIONS FOR COVERAGE OF JOISTS

30 minutes 1 x 18 mm

Joist Processing 3-fold covered

  • Material
  • 1 x 18 mm of 2 x 18 mm Permoxxboard.
    (look on basic of profile number in the processing book from page 48)
  • Handling
  • 1 x 18 mm Permoxxboard strips 100 mm broad between flanges. Underside coverage with 18 mm Permoxxboard 1200 mm long, riveted with 32 mm staples C-C 150 mm. Further covering Permoxxboard 18 mm riveted with 32 mm staples C-C 150 mm. (See diagrammes)
  • Seams
    For further finishing of the sight consult the processing advice on our website. www.permoxx.com. 
  • Seams 2 – 4 mm have always to be glued with fire-resistant glue or kit.
  • Edges (with or without demands for noise)
  • Not applicable
  • Test reports
    For fully detailed construction always consult the construction in the certificate
  • Fire-resistance:
    Efectis Raport: 2012-Efectis-R0531 en 2012-Efectis-R0532