img

PRCESS INSTRUCTIONS FOR COVERAGE OF JOIST

60 minutes 1 x 18 mm

Pillar processing 3- or 4-fold covered

  • Material
  • 1 x 18 mm Permoxboard. (Look on basic of profile number in the processing book from page 48)
  • Handling
  • 1 x 18 mm Permoxxboard strips 100 mm broad between flanges. Underside coverage with 18 mm Permoxxboard 1200 mm long, riveted with 32 mm staples C-C 150 mm. Further covering Permoxxboard 18 mm riveted with 32 mm with 32 mm staples C-C 150 mm. (see diagrammes)
  • Seams
  • for further finishing of the sight consult the processing advice on our website. www.permoxx.com
  • Seams
  • 2 – 4 mm have always to be glued with fire-resistant glue or kit
  • Edges (with and without demands for noise)
  • Not applicable
  • Test reports
  • For fully detailed construction always consult the construction in the certificate
  • Fire-resistance:
    Efectis Raport:
  • 2012-Efectis-R0531 and 2012-Efectis-R0532
  • img

PROJECTEN